Main fuse blowing

Need advice on which oil to use or which tyre best suits you? Share your topic and get help here.
lockwood1956
Posts: 176
Joined: Sun Aug 16, 2015 8:08 pm
Location: Knottingley West Yorkshire
Contact:

Main fuse blowing

Post by lockwood1956 »

Hi all

I decided on sunday with the weather being nice to start the bike up and go for a spin.

Turned ignition key....everything dead. did some research and discovered battery should have been charged more regularly (newbie...well oldie turned newbie) mistake.

Bought new battery and fitted, still dead. Turns out the main fuse was blown, I replaced it and when plugging the connector back in the fuse blew again!! (twice)

Thought I had better come back indoors and lick my wounds and seek help.

Bike running fine when put away in December. No work of any description carried out since.

Your thoughts/help/guidance much appreciated. thanks in advance.

cheers
bob
If at first you don't succeed.....sky diving isn't for you!

http://www.facebook.com/bob.morton.125
lockwood1956
Posts: 176
Joined: Sun Aug 16, 2015 8:08 pm
Location: Knottingley West Yorkshire
Contact:

Re: Main fuse blowing

Post by lockwood1956 »

Found this thread in the meantime!

http://www.vtr1000.org/phpBB3/viewtopic.php?f=9&t=781

I have a new Mofset regulator from Mac ready to fit (one of the jobs on my list)

Could this have failed whilst not in use? seems unlikely with bike not running, but what do I know?
If at first you don't succeed.....sky diving isn't for you!

http://www.facebook.com/bob.morton.125
User avatar
MacV2
Posts: 17539
Joined: Sun Jan 21, 2007 12:07 pm
Location: Grain

Re: Main fuse blowing

Post by MacV2 »

lockwood1956 wrote:Found this thread in the meantime!

http://www.vtr1000.org/phpBB3/viewtopic.php?f=9&t=781

I have a new Mofset regulator from Mac ready to fit (one of the jobs on my list)

Could this have failed whilst not in use? seems unlikely with bike not running, but what do I know?
Sounds daft but you havent connected the battery the wrong way round. + & - wrong way. That would blow the fuse.

Wont be the Mosfet if you havent fitted it...
Making up since 2007, sometimes it's true...Honest...
lockwood1956
Posts: 176
Joined: Sun Aug 16, 2015 8:08 pm
Location: Knottingley West Yorkshire
Contact:

Re: Main fuse blowing

Post by lockwood1956 »

MacV2 wrote:
Sounds daft but you havent connected the battery the wrong way round. + & - wrong way. That would blow the fuse.
Pretty sure the battery is on the right way round, but now I'm paranoid!


MacV2 wrote: Wont be the Mosfet if you havent fitted it...
Lol

I meant the old regulator, not the replacement one from your good self
Last edited by lockwood1956 on Wed Mar 09, 2016 9:15 pm, edited 1 time in total.
If at first you don't succeed.....sky diving isn't for you!

http://www.facebook.com/bob.morton.125
lockwood1956
Posts: 176
Joined: Sun Aug 16, 2015 8:08 pm
Location: Knottingley West Yorkshire
Contact:

Re: Main fuse blowing

Post by lockwood1956 »

I'm thinking that it wasn't the battery at fault in the first place.

There must be a short for the fuse to blow in such a way ( twice)
Just can't work out why this has happened when bike not in use?
If at first you don't succeed.....sky diving isn't for you!

http://www.facebook.com/bob.morton.125
User avatar
Duffy1964
Posts: 2946
Joined: Mon Jul 25, 2011 4:15 pm
Location: Orpington Kent

Re: Main fuse blowing

Post by Duffy1964 »

I had a problem with my first storm, I hadn't moved or charged the battery but while riding at died on me, like you I changed main fuse a couple of times and they blew straight away.

Contacted Mr Mon and he correctly diagnosed that my original rectifier was shot, fitted a new one job done :thumbup:
Duffy1964
Yellow 1997 Storm R.I.P. Orange 2000 Streetfighter (Rufus), Red & Silver 1968 Triumph Trophy 650, Blue 2003 Storm Project, Red 2007 Montesa Cota Trials 250 & 1959 BSA D7 175cc Bantam Trials Project
lockwood1956
Posts: 176
Joined: Sun Aug 16, 2015 8:08 pm
Location: Knottingley West Yorkshire
Contact:

Re: Main fuse blowing

Post by lockwood1956 »

The thng that I can't get my head around is it all going pear shaped whilst hibernating.

Turned key on Sunday to find all dead, no signs of life at all :(
If at first you don't succeed.....sky diving isn't for you!

http://www.facebook.com/bob.morton.125
User avatar
Duffy1964
Posts: 2946
Joined: Mon Jul 25, 2011 4:15 pm
Location: Orpington Kent

Re: Main fuse blowing

Post by Duffy1964 »

Yep that would puzzle me too, but I dose seem like your rectifier is the cause if you have touched nothing else, or maybe a rusty starter motor connection that is arcing out causing the fuse to blow?
Duffy1964
Yellow 1997 Storm R.I.P. Orange 2000 Streetfighter (Rufus), Red & Silver 1968 Triumph Trophy 650, Blue 2003 Storm Project, Red 2007 Montesa Cota Trials 250 & 1959 BSA D7 175cc Bantam Trials Project
User avatar
sirch345
Site Admin
Posts: 21856
Joined: Mon Aug 25, 2003 10:35 pm
Location: The West Country.

Re: Main fuse blowing

Post by sirch345 »

MacV2 wrote:
Sounds daft but you havent connected the battery the wrong way round. + & - wrong way. That would blow the fuse.
I was thinking that as well. The live (+) terminal of the battery should be on the lefthand side (gear change side) of the bike. If it's not that, then I also suspect it's the rectifier that's gone,

Chris.
tony.mon
Posts: 16022
Joined: Wed Jul 25, 2007 10:46 pm
Location: Norf Kent

Re: Main fuse blowing

Post by tony.mon »

One other possibility is mice chewing insulation off a wire or two and causing a dead short.
But you can check easily enough- just unplug the RR and see if it still does it.
It's not falling off, it's an upgrade opportunity.
lockwood1956
Posts: 176
Joined: Sun Aug 16, 2015 8:08 pm
Location: Knottingley West Yorkshire
Contact:

Re: Main fuse blowing

Post by lockwood1956 »

Live terminal def on the near side ( left)

Not touched the regulator as yet, hence my puzzlement re failure

Will check connections to starter

If it were the regulator, if I unplugged it and changed the fuse, without plugging regulator back in would this test it?bor would it be breaking the circuit to other potential problem areas?

Just thinking out loud and hoping it makes sense
If at first you don't succeed.....sky diving isn't for you!

http://www.facebook.com/bob.morton.125
lockwood1956
Posts: 176
Joined: Sun Aug 16, 2015 8:08 pm
Location: Knottingley West Yorkshire
Contact:

Re: Main fuse blowing

Post by lockwood1956 »

tony.mon wrote:One other possibility is mice chewing insulation off a wire or two and causing a dead short.
But you can check easily enough- just unplug the RR and see if it still does it.
Cheers Tony

We were posting at the same time
If at first you don't succeed.....sky diving isn't for you!

http://www.facebook.com/bob.morton.125
lockwood1956
Posts: 176
Joined: Sun Aug 16, 2015 8:08 pm
Location: Knottingley West Yorkshire
Contact:

Re: Main fuse blowing

Post by lockwood1956 »

Removed connector from regulator and everything lit up fine

I can't get my head around the fact that it blew when not in use!!!

Regulator replaced with mofset one supplied last year by MacV2 ( cheers Mac)

Running a treat now

Thanks for the help guidance and advice chaps, Tis much appreciated, whilst I had the rear fairing off I fitted the grab rail I purchased last year too.

Handlebar conversion next on the list, have the bits and a set of flats and a set of 1" rise. May tackle it this weekend, not sure f I will need extended brake hoses, I suspect with the flat bars I might just get away with it :thumbup:
If at first you don't succeed.....sky diving isn't for you!

http://www.facebook.com/bob.morton.125
User avatar
sirch345
Site Admin
Posts: 21856
Joined: Mon Aug 25, 2003 10:35 pm
Location: The West Country.

Re: Main fuse blowing

Post by sirch345 »

lockwood1956 wrote:Removed connector from regulator and everything lit up fine

I can't get my head around the fact that it blew when not in use!!!

Regulator replaced with mofset one supplied last year by MacV2 ( cheers Mac)

Running a treat now

Thanks for the help guidance and advice chaps, Tis much appreciated, whilst I had the rear fairing off I fitted the grab rail I purchased last year too.

Handlebar conversion next on the list, have the bits and a set of flats and a set of 1" rise. May tackle it this weekend, not sure f I will need extended brake hoses, I suspect with the flat bars I might just get away with it :thumbup:
Good to hear you've fixed the problem :D

You'll probably need to extend the horn wire, the rest should be okay with that conversion, different if you had a higher bar conversion. Post up some pic's when you're done :thumbup:

Chris.
lockwood1956
Posts: 176
Joined: Sun Aug 16, 2015 8:08 pm
Location: Knottingley West Yorkshire
Contact:

Re: Main fuse blowing

Post by lockwood1956 »

sirch345 wrote:Post up some pic's when you're done

Will do :wave:
If at first you don't succeed.....sky diving isn't for you!

http://www.facebook.com/bob.morton.125