I want to cut out the burnt wire and solder in a new piece.
Here's the culprit:-

Thanks,
Chris.
Quick off the draw Eric !E.Marquez wrote: ↑Thu Jun 27, 2019 10:04 pm Japanese bikes use a metric wire size that is not a direct cross over to AWG or anything else commonly available in the UK or US.
it would be about 19 AWG if it was a thing, as its not I use 18 AWG, high strand tinned Marine rated wire or M22759/16 Tefzel 18 AWG wire.
That is a perfect replyE.Marquez wrote: ↑Thu Jun 27, 2019 10:04 pm Japanese bikes use a metric wire size that is not a direct cross over to AWG or anything else commonly available in the UK or US.
it would be about 19 AWG if it was a thing, as its not I use 18 AWG, high strand tinned Marine rated wire or M22759/16 Tefzel 18 AWG wire.
BUT I would not patch that .. I would make a new cable, RR to stator connector
![]()
You were spot on there CarlVTRDark wrote: ↑Thu Jun 27, 2019 9:48 pm Now there's a good question. You need an Erik viewtopic.php?f=9&t=43293 I bet he knows exactly what gauge it is.
I meant to post this up before nowE.Marquez wrote: ↑Thu Jun 27, 2019 10:04 pm Japanese bikes use a metric wire size that is not a direct cross over to AWG or anything else commonly available in the UK or US.
it would be about 19 AWG if it was a thing, as its not I use 18 AWG, high strand tinned Marine rated wire or M22759/16 Tefzel 18 AWG wire.
BUT I would not patch that .. I would make a new cable, RR to stator connector
![]()
Chris, Best I can tell from parts fiche there is no different in stator wiring for any region. And Im pretty sure on my measurements, having done it with a micrometer under magnification so I could be sure I was getting a good read on wire.. but that aside...as I think it makes little difference ...sirch345 wrote: ↑Tue Jul 23, 2019 8:31 pmI meant to post this up before nowE.Marquez wrote: ↑Thu Jun 27, 2019 10:04 pm Japanese bikes use a metric wire size that is not a direct cross over to AWG or anything else commonly available in the UK or US.
it would be about 19 AWG if it was a thing, as its not I use 18 AWG, high strand tinned Marine rated wire or M22759/16 Tefzel 18 AWG wire.
BUT I would not patch that .. I would make a new cable, RR to stator connector
![]()
![]()
Anyway, I ordered up some 18AWG wire, but when it arrived it was a lot thinner than what my OEM wiring is going from the alternator terminal block to the rectifier. After some calculations, it appears my wires are nearer to 16AWG (to the best of my ability each strand of my existing wires measure 0.19mm dia X 50 strands).
I'm not meaning to sound like I'm knocking what you have said Erik, far from it you've been more than helpful, but I do wonder if the UK version of the firestorm has thicker wires in that departmentand that's why I thought I better mention it in case anyone else reads this,
Chris.
Erik, thanks for your reply.E.Marquez wrote: ↑Thu Jul 25, 2019 10:47 pm
Chris, Best I can tell from parts fiche there is no different in stator wiring for any region. And Im pretty sure on my measurements, having done it with a micrometer under magnification so I could be sure I was getting a good read on wire.. but that aside...as I think it makes little difference ...
Going about it from the opposite way around is actually not a bad idea.
I haven't had the luxury of finding a supplier local to me with a known quality name for my wiring so far, or certainly not in short lengths. The 18 AWG wire I purchased was a temporary measure so my bike wasn't off the road any longer as the summer is here. Yes is was marketed as 18 AWG. However as that 18 AWG wire was definitely thinner than the OEM, my local motorcycle repair shop was able to supply me with a length of wire which I worked out to be slightly thicker than the OEM is. No manufactures name again.E.Marquez wrote: ↑Thu Jul 25, 2019 10:47 pm Also, what wire did you order and measure to compare? How many strands? what was the cross section of each? Was it a known quality name brand or standard wire ..or just a marketed "18 ga"?
I ask as not all wire is created equal, as well as its really hard to visually compare 10 strand xx ga against 32 or 16 strand xx ga. as well as insulation difference can make the wire size difference visually confusing